ADC Telecommunications Inc. DSR0805A Manual Do Utilizador

Página de 17
ADCP-75-163WB • Issue 1 • August 2004
Page 10
© 2004, ADC Telecommunications, Inc.
Figure 3. Optical Ports (Transceiver Sockets)
Use the following procedure to install the forward and reverse path optical fibers and to connect
them to the WBDR PCIx Host card: 
1. Obtain the required lengths of single-mode fiber optic cable. 
2. Route the fiber optic cable between the WBDR PCIx Host card and the remote (radio head)
unit (if not already routed) and cut to required length. Allow sufficient slack for dressing and
organizing the cables at each unit. Maintain a minimum bend radius of 2 inches (50 mm).
3. Terminate each optical fiber with a field-installable LC type fiber optic connector as
shown in 
. Follow the instructions provided by the connector manufacturer for
installing the connector. 
4. Test each fiber for optical loss. 
5. Designate one of the fibers as the forward path fiber and the other as the reverse path fiber
and label both ends of each fiber with the path designation. 
6. Use the plastic joiner provided with the LC connectors to join the WBDR PCIx Host card
forward and reverse path connectors together (see 
). Make sure the forward path
and reverse path connectors are oriented as shown.
Note: Maximum path length for 9/125 single-mode fiber optical fiber is 10 km (32,808 ft.).
19309-A
TRANSCEIVER
SOCKETS