2.1.1.8.4.  Set Range 
This Digicall Spectrum
 system accommodates classes up to 63 students. The “AUTOMATIC 
SEQUENCER” is factory set to monitor student transceiver numbers “1” through “99” (99 headsets). 
Most classes have fewer than 99 students. In order to save searching time in the automatic mode, the 
range of the “AUTOMATIC SEQUENCER” should be set for your class size. To do this, complete 
the following steps: 
1.  Press the “SET RANGE” button. The letters “HI” will appear in the display. 
2.  Press the “SET RANGE” button a second time and the number 99 (or the last “HI” value) will 
show in the display. Enter the highest number headset in your class.  
3.  After entering this number, press the “SET RANGE” key again. At which time the letters 
“LO” will appear in the display.  
4.  Press of the “SET RANGE” button again. The number “1” (or the last “LO” value) will 
appear in the display. If the lowest numbered student unit in your class is greater than “10” 
enter that number in the display. 
5.  Pressing of the “SET RANGE” button again returns the console to the monitor mode. The 
“AUTOMATIC SEQUENCER” will now be reset to the highest and lowest numbered unit in 
the class. 
If you wish to review the student unit numbers stored in the “HI” and “LO” memory, press 
the “SET RANGE” key again after the “HI” or “LO” appears. The high and low student unit 
numbers will appear on the display. 
NOTE: Each time your console is turned off, the “AUTOMATIC SEQUENCER” will 
remember the range settings for the next session. 
2.1.1.8.5.  Set Period 
To change the length of time that each student is automatically monitored when using the 
“AUTOMATIC SEQUENCER”, press the “SET PERIOD” button and notice the “SP” on the 
display. Pressing “SET PERIOD” again will show the present timer setting, in seconds, on the 
display. If you wish to change the setting, enter a new number. The timer may be set from 1 second to 
99 seconds. For numbers 01 to 09, the leading “0” must be entered. Press the “SET PERIOD” or 
“CLR” to return the console to the normal monitoring mode.  
NOTE: Each time your console is turned off, the “AUTOMATIC SEQUENCER” will 
remember the period range setting for the next session. 
2.1.1.9. Save/Recall 
The Digicall Spectrum
 system allows an instructor to save individual preferences for future recall.  
The instructor can save Period and Range settings, volume settings, and the last lesson used in 10 
different memory locations.  This allows customized settings to be quickly restored for up to 10 
different instructors or classes.