5.4. Walk Test       
This is to test the sensor operation range for installation purpose.   
Step 1.  Click on “Start”. The Control Panel LED 1 & LED 2 Green Flash is now in Walk Test 
mode. The system will automatically exit the test mode after 5 minutes   
             
Step 2.  Press the test button on the sensor(s) or any button on the Remote Controller or 
triggering the sensor.   
Step 3.  When the Control Panel receives a signal, it will show as below and a 2-tone beep will 
be heard to indicate that it is safe to install the particular sensor in the location.   
 
Time: time informaiton     
 
Area: operation area   
 
Zone: device zone     
 
Type: device type   
 
Name: device name     
 
Rssi: the RF signal strength between Control Panel and sensor. The Rssi value here 
must be higher than the Rssi value of Panel’s background noise (please refer to 6.1 
Panel Condition section for details). If not, you may still learn in the sensor; however, 
please relocate the sensor and use Walk test to find a more suitable location. 
 
DeviceID: device’s unique identification code. 
Step 4.    Once all sensors are tested, click on “Stop” to exit Walk Test mode.