Tyco Safety Products/Sensormatic AMB9020 Manual Do Utilizador

Página de 12
Preliminary 2003-11-21 
DUAL ANTENNA SCANMAX PRO DEACTIVATOR CONTROLLER 
8200-0365-01, REV. 1A 
INSTALLATION AND SERVICE GUIDE 
2 of 12
 
About the Product 
Product Overview 
The Dual Antenna Deactivator controller supports 
any two ScanMax Pro deactivation antennas used 
to deactivate USII and USIII labels. A universal 
input, 22Vdc output power supply powers the 
controller. 
The controller contains the necessary ports for:  
•  Wireless synchronization  
•  Network communication 
•  Maintaining independent antenna status 
•  Functional control for each antenna.  
The controller also has:  
•  Automatic antenna type detection, except if 
using the optional extension cable. 
•  Auto synchronization  
•  Automatic key switch detection  
•  Panel button for Label type (SR or DR) and 
power level (Full or Magnetic Media Safe) 
•  LEDs that indicate power on, communication 
activity, and diagnostics. 
Product Limitations  
•  The controller has max duty cycle of three 
times a second. 
•  Both antennas must have the same power 
level and label type  
•  Max throughput speed of 203cm/sec 
(80”/second) unless otherwise limited by the 
antenna.  
•  Maximum distance between antenna and 
controller is expected to be 3m (9.8ft), or 6m 
(19.7ft) when optional extension cable 0652-
0136-01 is used.  
•  Antennas cannot deactivate simultaneously. 
•  No independent antenna power selection  
(both antennas full or MMS) 
•  No independent antenna label selection  
(both antennas same label setting) 
•  Low Profile Pad and PowerPad have a 10% 
reduction in deactivation height. 
Magnetic Media Safe Operation 
Magnetic Media Safe (MMS) operation enables 
security labels in audiotapes and videotapes to be 
deactivated without affecting the media. MMS is 
selectable using a software configurator, or using 
the push button on the controller. 
Synchronization 
Auto-synchronization. Auto-synchronization 
within the controller helps minimize tuning and 
adjustment service calls. The controller 
synchronizes to the antenna picking up the highest 
in-band amplitude or to a wireless synchronization 
input.  
Wireless synchronization. The wireless 
synchronization module plugs into the RS485 port 
on the controller. If the TSP/Sensormatic network 
is using this port, the module can be plugged into 
the modular jack of the network terminal block 
assembly.  
About the Controller 
The controller consists of an aluminum and plastic 
enclosure that contains power and control 
electronics. All connections are made to a 
connector plate on one side of the unit.  
Connections include:  
•  DC power in 
•  Two deactivation outputs 
•  Two remote indicator ports 
•  Two RS232 ports: POS 1 and POS 2 (the 
service configurator uses only the POS 1 port) 
•  Two Scan I/O ports 
•  RS485 port. 
Connector Panel 
Antenna 1 
Antenna 2 
Remote 1 
Remote 2 
LED for mag media safe (MMS) 
LED for label type (SR) 
Button: PROG 
Control LED: Status 1 and Status 2 
POS1/SERV 
POS2 
RS485 
Scan IO 1 
Scan IO 2