MXI1503-2004 OPERATIONS AND MAINTENANCE 
PUB13-10 Rev 1 
AMPLIFIER INSTALLATION AND STARTUP 
The  MXi  Amplifier  was  fully  tested  at  LARCAN  before  it  was  delivered.  Under  normal  circumstances,  the 
transmitter can be fully operational with minimal setup when turned ON. However, a good practice is to take the 
“start from scratch” approach, which means that one should take precautionary measures before the amplifier is 
allowed  to  run  at  full  rated  power.  These  important  steps  will  avoid  any  catastrophic  failures  at  start-up.  The 
procedure described  is essentially  the same approach taken at the factory  with a new  and untested transmitter. 
This also applies if there is a need to completely replace a major sub-assembly in the transmitter. 
5.1  B
EFORE 
A
PPLYING 
AC
 TO THE 
U
NIT
 
Pay  careful  attention  to  items  1  to  3  before  applying  AC  to  the  amplifier.  These  are  initial  steps  that  must  be 
observed and followed for proper and safe operation of the amplifier. 
1.  Termination 
 
Ensure that the amplifier is properly terminated with a suitable load. This can be into a dummy load or into 
the  transmitter  output  system.  A  50  Ohm,  1kW  load  with  at  least 
–20dB  return  loss  (1.2  VSWR)  is 
recommended.  Preferably,  directional  couplers  with  known  coupling  levels  at  the  frequency  of  interest 
should  be  connected  at  the  input  and  output  of  the  band-pass  filter.  These  points  are  very  useful  in 
determining absolute power levels and losses, and also for use as an RF sample for monitoring purposes. 
See Figure 10 for a typical transmitter test equipment setup. 
2.  Interlocks 
Interlocks  must  be  connected  to  the  amplifier  to  avoid  damage  to  the  equipment  and  to  the  output  section. 
The  overall  interlock  is  located  on  the  rear  panel  of  the  Main  Control  chassis 
and it is labeled INT’K. If this 
interlock is open, the +50V to each Amplifier will shut down, including the cooling fans. 
 
3.  Power At Minimum 
 
Initially, the modulator’s output should be at minimum level.  
5.2  A
PPLYING 
AC
 TO THE 
U
NIT
 
 
Check  that  the  AC  going  into  Main  AC  Breaker  ranges  from  190-264VAC.  If  this  is  so,  proceed  to 
applying power, otherwise, investigate the source of the problem. 
 
Usually, once the AC is applied to the breakers and the breakers are in the on position, the Control Power 
Supply turns ON and applies +12V to the Main Controller and the controller in each amplifier. 
 
The Power-Up screen will be displayed on the LCD, followed immediately by the Main Menu. 
 
 
Figure 3 Main Menu 
5.3  B
EFORE 
T
URNING THE 
A
MPLIFIER 
ON 
From  the  Main  Menu,  the  status  of  the  amplifier  is  displayed  and  shows  if  the  amplifier  is  ready  for  operation. 
Status legends, when lit, such as the INTK (INTERLOCK), usually signify OK conditions and that the transmitter is 
ready to be switched ON. 
Check that all of the following conditions are met: 
1. 
Modulator and up-converter, or Channel Processor is ready.