MXI1503-2004 OPERATIONS AND MAINTENANCE 
PUB13-10 Rev 1 
2.  Monitor the +50V power supply voltage and currents on the LCD. Check that the power supplies are operating 
by pressing the P/S touch button. The voltage readings should be about 50V and the currents should be about 
45-50 Amps per module under full power. 
ALLOW THE AMPLIFIER SOME WARM-UP TIME! 
Only  after  the  transmitter  has  been  ON  for  approximately  15  minutes  should  you  perform  the  fine 
adjustments.  The  amplifiers  must  be  allowed  to  reach  their  operating  temperature  for  stable  operation.  The 
Power  Amplifiers  in  the  MXi  transmitter  are  equipped  with  thermal  compensation  circuits,  which  reduce  the 
output  power  when  the  temperature  rises.  Therefore,  the  operating  temperature  must  be  reached  before 
adjusting  the  RF  level  to  its  proper  level,  i.e.  100%.  The  amplifiers  are  also  equipped  with  Automatic  Gain 
Control, primarily designed to prevent the transmitter from overpower or overdrive condition. 
3.    Increase  the  RF  output  by  slowly  turning  the  Modulator/Exciter  or  Channel  Processor  output  level  control.     
Stop  at  about  25%  output  power  indicated  on  the  LCD.  At  this  level,  the  current  should  be  around  than  20 
Amps per amplifier.  Current will vary with channel. 
4.  If  the  current  is  not  drastically  higher,  increase  the  power  to  50%.  Again,  make  note  of  the  PS  current 
readings.  The  current should  be  around  26  Amps  per  amplifier.  Proceed  to  the  next  step  if  this  condition  is 
met. 
5.  Increase the RF output to 100%. The current should be about 45A-50A per amplifier normal video signal. 
6.  AGC SETTING: The AGC is setup at the factory for each amplifier.  You can raise and lower the AGC level 
on the touchscreen under the Comb (combined) submenu.  When you select the button to raise or lower the 
AGC a command is sent to each amplifier to raise or lower the level the same amount.   
 
Figure 6 AGC Adjustment 
The AGC setup of each amplifier should not be adjusted under normal operating conditions.  It should only be 
change if you are changing channels.  For instructions on AGC setup of the amplifiers see Section 6.1.5 
7.  With  the  amplifiers  fully  functional  and  adjusted  to  final  settings,  record  keeping  becomes  very  important. 
Record the current, voltage, power, etc. This data can be used as a very valuable troubleshooting tool later. 
Below is typical test data pertaining to the Revive amplifiers at 100% output power. 
 
5.4.2  TYPICAL DATA read on the LCD 
Combined 
COMB  100%   
AMP1  100%     
AMP3  100%   
 
RFL 
0.5% 
 
AMP2  100%   
AMP4  100% (In the case of a MXi2004) 
 
 
Amplifier 
FWD 
 
100%   
RFL 
 
1.0% 
AGC 
 
1.0V 
 
CUTB   
0.0V 
 
Power Supply 
PS  VOLTS 
50.0V   
PS CURR 
47A