5.6.2
Connecting AC Power
The PMU is designed to accept a mains input of 88 to 264 VAC at 45 to
65 Hz. A standard 3-wire grounded socket outlet must be used to supply the
AC power. The socket outlet must be installed near the equipment and must
be easily accessible. This outlet should be connected to an AC power supply
capable of providing at least 600 W. The requirements of two typical AC
supplies are given in the following table.
65 Hz. A standard 3-wire grounded socket outlet must be used to supply the
AC power. The socket outlet must be installed near the equipment and must
be easily accessible. This outlet should be connected to an AC power supply
capable of providing at least 600 W. The requirements of two typical AC
supplies are given in the following table.
Your
base station
should come supplied with
a power supply cord to connect the male
IEC connector on the PMU to the local AC
supply. The pins of the IEC connector on
the PMU are identified at right.
IEC connector on the PMU to the local AC
supply. The pins of the IEC connector on
the PMU are identified at right.
Nominal Supply
Current Requirement
a
a. The actual current consumption of the
base station
will be lower than these require-
ments (refer to the Specifications Manual for more information).
Circuit Breaker/Fuse
Rating
Rating
a
115 VAC
8 A
10 A
230 VAC
4 A
6 A
ground
rear view
neutral
phase