- FCC text added 
 
 
 
 
PROM overview CPS4FSS 
 
 
 
CPS4FSI 0.04 
first release with inverse motor contact 
 
 
CPS4FSS 1.00  motor installation menu added 
 
 
CPS4FSS 2.00  -  Menu of the Self test (St) is automatically adjusted to the found 
values during the output configuration test (Oc). 
-  Modification of motor routine, analogue in stead of digital. 
-  Modification for factory test : by pushing the button during start up 
the menu for tuning the HF-field will appear automatically. After 
pushing the button the responder test menu will appear. This 
function can also be used at installation/test. 
-  Modification for single feeder 2 : 
  extra in- and output 
  squelch menu, SF depending on type 
 
 
CPS4FSS 3.00  Identification : The prom is capable to identify future phase-code 
activity responders. 
Feedmotor : The feedmotor may consume a higher current before 
the transmitter receiver signals an error. 
St Menu : The test menu will not jump automatically to the next 
menu item after testing an in- or output 
Relay output : When an output is configured as a relay output it is 
possible to block the feeding temporarily. The transmitter 
receiver will always first read the input before the output is 
activated.  The program will only then continue to activate the 
outputs when the blocking  input is ‘high’ (no connection with I-). 
Responder Selection : An AM code (X-ponder and Respactor) and 
a PM code (earbutton and phase code activity) can not be 
identified simultaneously. A selection item is introduced in the HF 
menu of the Single 2 transmitter receiver to select one of these 
modes. This selection item is called rS (responder select). You 
can make a choice between either rA, for AM code carriers, or  
rP voor de PM code carriers. 
Squelch : The adjustment of the squelch in four levels is re-
introduced (0,-1,-2,-3 instead of on/of). The default value for the 
squelch level depends on the transmitter receiver type and the 
choice of code carrier. 
 
 
CPS4FSS 3.05  -  Suitable for HC11E1 micro processor (yellow sticker) 
-  SF2 with 4 outputs: operation of motor on output 4 improved  
-  Menu settings for neutrodynistation have been added. 
-  When overloaded, the time after which the transmitter/receiver 
switches the output off, is set higher. This means that during 
congestion or blockade of the auger the motor remains switched 
on longer. 
 
 
CPS4FSS 3.08  2-hour activity added (Lactivator) 
 
 
CPS4FSS 4.00  Program change for use with SF model 2, 3 and 4