4 Executing the installation
When all the preparations are taken into account, the installation of the system can take place. The installation
consists of physically mounting the system in the right orientation, installing the cabling and applying power
to the system.
Conduit or slit
We always advise to place a conduit, as this allows easy replacement of cables when necessary. If not
possible, a slit can be made as well.
When a system is going to be upgraded to RFID in the future, please make sure to install a conduit to
add the RFID coax cable in the future. You can also choose to install the RFID coax cable already. This
is especially important when relying on a floor cut.
The conduit or slit in which the cables are placed, should be exactly in the middle of the antenna,
perpendicular to the antenna. This is explained in the following pictures.