2.4 
DATA COLLECTORS 
The actual status (occupancy) of the SENSIT sensors is collected by one or more Data 
Collector. The Data Collector is the interface between the
 
wireless sensors network and the 
SENSIT Interface Software running at the server. The Data Collector transmits status 
information about the sensors to the server using TCP/IP Ethernet communication. 
 
For a parking site you need at least one Data Collector, a Relay Node and a SENSIT per 
parking bay. One Data Collector is required per 250 parking bays. All Data Collectors must 
be separated as far as possible from each other, preferably at the remote corners of the site. 
The Data Collector is available in 2 different versions: the standard Data Collector and the 
Data Collector GPRS. 
 
2.4.1  STANDARD DATA COLLECTOR  
The Data Collector can be mounted in a central enclosure, 
however please ensure that the enclosure is not made of metal. 
The Data Collector is featured with RF communication with the 
SENSIT. The material used for the enclosure should be 
transparent for RF signals. 
 
Data Collector 
Operating 
frequency 
SENSIT DATACOLLECTOR EU: 868.2 MHz 
SENSIT DATACOLLECTOR CN: 868.2 MHz 
SENSIT DATACOLLECTOR US: 902-928 MHz (FHSS) 
SENSIT DATACOLLECTOR AU: 915-927 MHz (FHSS) 
Dimensions 
125 x110 x 65 mm   
 
(4.9 x 4.3 x 2.6 inch) 
Weight 
105 gram  
 
 
(3.7 oz) 
Protection 
IP44 
Operating 
temperature 
-0°C … +55°C  
 
 
(32°F … +85°F) 
Humidity 
10%...90% relative humidity, non-condensing 
Communication 
range* 
From SENSIT to Data Collector in principle unendless as the 
nodes communicate to each other. It is recommended to 
locate the nearest Relay Node within 25 meters (82 ft) of the 
Data Collector. 
Communication 
RJ45 TCP/IP (or RS232 DIN-9 F) 
Power input 
5 VDC power adapter included 110-240 VAC. 
Antenna 
connection 
Antenna included 
* Dependent on the environment.