N. V. Nederlandsche Apparatenfabriek NEDAP SENSITEPL Manual Do Utilizador

Página de 92
SENSIT SYSTEM | MANUAL 
Mounting The Relay Node 2G
 
 
38/92 
7.7 
 BATTERY REPLACEMENT 
When the battery life of the Relay Node 2G fails after specified lifetime, the batteries can be 
changed make sure you use the right batteries: 
 
D-cell Lithium Thionyl Chloride batteries (Li-SOCl
2
) 3.6V, recommended types are: 
 
SAFT | LS 33600  
 
XENO | XL-205F 
 
SENSIT Relay Node 2G battery replacement 
 
Step 1:   
Opening the housing 
Open the Relay Node 2G housing by 
unscrewing the TORX, T20 screw.  
 
Step 2:  
Replace the batteries 
Remove the old batteries and dispose 
them in the correct manner. Place the 
new 3.6V Lithium (Li-SOCL
2
) batteries 
(see suggested types above) and make 
sure the polarity is correct, as indicated.  
 
Step 3:  
Verify start-up  
Green LED starts blinking fast (duration: 
15 sec.), indicating that battery power 
has been connected correctly.  
 
 
 
Step 4: 
 WSN search 
 
Red LED starts to blink slowly. This 
indicates that the Relay Node didn’t 
found an active WSN (wireless SENSIT 
Network) yet. It is searching for a WSN. 
 
 
Step 5:  
WSN found 
Green LED starts slow blinking and red 
LED is turned off. This indicates that a 
WSN has been found.  
 
 
Step 6:  
Final installation 
Now the Relay Node electronics can be 
installed at the pole or wall with a TORX 
(T20) screw driver.  
 
 
 
 
 
Note 
The Green and Red feedback 
LED’s are located in the 
yellow circle. 
 
Note 
After 15 minutes LED 
feedback is turned off, to save 
battery power. 
 
Note 
After 1 minute the LED 
feedback is turned off, to save 
battery power.