Mounting The SENSIT IR
 
 
41/92 
8.6 
INSTALLATION PROCEDURE 
Below the mounting procedure for the SENSIT 
sensor
.  
 
SENSIT sensor mounting procedure 
 
Step 1: 
Preparation 
Indicate on the closed parking lot where the 
SENSIT sensor should be mounted. Distribute 
the SENSIT sensors over the parking lot and 
write down the correct ID numbers on your 
installation plan. 
 
Step 2:  
Drilling 
Drill a hole of Ø 85 mm [
3.35 in]
 and at least 55 
mm [2.16 in] deep into the centre of the parking 
bay 
 
Step 3:  
Gluing  
Apply the right amount of filler and pour into the 
hole. 
 
Step 4: 
Mounting 
 
Double-check the node ID number and the 
parking bay on the installation plan and place the 
SENSIT sensor into the hole. 
 
 
Step 5:  
Cleaning-up 
After mounting the SENSIT sensors in all parking 
bays or a selection of parking bays. Clean up the 
parking bays and remove all (metal) tools and 
objects. 
 
Step 6:  
Activating 
All SENSIT sensors are set into transport/stock 
mode during shipment. After installation all 
mounted SENSIT sensors must be swept with 
the reset magnet.  
 
Step 7: 
Calibrating 
After installation the SENSIT sensor must be 
calibrated. Ensure that the parking space is 
empty and that there is no car parked on top of 
the sensor or on neighboring parking bays. 
SENSIT sensors can be calibrated via the SENIST 
Interface Software (SIS). See chapter 13.6.6 for 
more information about calibration.  
 
Step 8:  
Glue curing 
Leave the filler harden for 8 hours before 
vehicles are allowed in the parking space again. 
 
 
8.7 
REPLACEMENT 
When the battery life of the SENSIT IR fails after specified lifetime, we advise to replace the 
unit completely.  The SENSIT IR is fully sealed and for outdoor use, therefore batteries 
cannot be replaced. 
Drill out the old SENSIT IR and complete the mounting procedure as describe in the 
previous paragraph.  
 
Ensure to note the node ID number of the SENSIT IR to the parking bay. Update the parking 
bay configuration list in the SIS software to ensure the new sensor is linked to the right 
parking bay.    
 
 
Note 
Take attention that you fixate 
the SENSIT sensor during the 
curing time otherwise the 
sensor will start to float. 
 
 
 
 
 
Note 
Once out of the 
transport/stock mode the 
battery lifetime starts to 
count. 
 
Note 
When the SENSIT sensors are 
not calibrated they hardly 
send any messages. This is 
due to the fact that there are 
no events generated because 
the magnetic thresholds are 
not crossed.