N. V. Nederlandsche Apparatenfabriek NEDAP SENSITGW Manual Do Utilizador
SENSIT SYSTEM | MANUAL
Mounting The Relay Node 2G
48/111
Mounting The Relay Node 2G
INSTALLATION CONDITIONS
The installation recommendation is based on the following environmental
conditions;
conditions;
x
Dry weather conditions.
REQUIRED INSTALLATION MATERIALS
The following would be required for mounting of the SENSIT Relay Node 2G.
x
Special Equipment:
Ladder, Bucket-truck or an aerial platform
x
TORX screw driver:
T20
x
Allen key:
no. 5
x
Wrench:
size
10
INSTALLATION PROCEDURE
Below the mounting procedure for the Relay Node 2G. The Relay Node 2G features
visual status feedback using two LED indicators: a green and a red LED.
visual status feedback using two LED indicators: a green and a red LED.
SSENSIT Relay Node 2G mounting procedure
SStep 1:
Mounting
Mounting
Mount the reflector and top of the
housing on the pole or wall. With the
Nedap asterisk at the top. The Relay
Node 2G can also be mounted without
the reflector for an omni-directional
radiation pattern.
housing on the pole or wall. With the
Nedap asterisk at the top. The Relay
Node 2G can also be mounted without
the reflector for an omni-directional
radiation pattern.
SStep 2:
Power the
Relay Node
Relay Node
Remove the isolation tabs, to power up
the Relay Node.
the Relay Node.
SStep 3:
Verify start-up
Verify start-up
Green LED starts blinking fast (duration:
15 sec.), indicating that battery power
has been connected correctly.
15 sec.), indicating that battery power
has been connected correctly.
SStep 4:
WSN search
Red LED starts to blink slowly. This
indicates that the Relay Node didn’t
found an active WSN (wireless SENSIT
Network) yet. It is searching for a WSN.
indicates that the Relay Node didn’t
found an active WSN (wireless SENSIT
Network) yet. It is searching for a WSN.
SStep 5:
WSN found
WSN found
Green LED starts slow blinking and red
LED is turned off. This indicates that a
WSN has been found.
LED is turned off. This indicates that a
WSN has been found.
SStep 6:
Final
installation
installation
Now the Relay Node electronics can be
installed at the pole or wall with a TORX
(T20) screw driver.
installed at the pole or wall with a TORX
(T20) screw driver.
Note
When segmentation is
needed, please use the
Configuration Tool and set
the right segment.
Note
The Green and Red
feedback LED’s are located
in the blue circle.
Note
After 15 minutes LED
feedback is turned off, to
save battery power.
Note
After 1 minute the LED
feedback is turned off, to
save battery power.
When segmentation is
needed, please use the
Configuration Tool and set
the right segment.
Note
The Green and Red
feedback LED’s are located
in the blue circle.
Note
After 15 minutes LED
feedback is turned off, to
save battery power.
Note
After 1 minute the LED
feedback is turned off, to