11  MOUNTING THE SENSIT IR 
 
SAFETY PRECAUTIONS 
The following safety precautions should be observed during normal use, service and 
repair: 
The SENSIT 
IR
 may only be installed and serviced by qualified service 
personnel. 
To be sure of safety, do not modify or add anything to the SENSIT 
IR
 other 
than mentioned in this manual or indicated by NEDAP N.V. 
 
 
 
IC AND FCC ID 
FCC ID: CGDSENSIT and IC: 1444A-SENSIT 
 
 
DIMENSIONS 
The SENSIT 
IR
 is designed for mounting into the floor of a parking space. See Figure 
34 for the dimensions of the unit in mm. 
 
Figure 34: Dimensions SENSIT IR (mm). 
 
INSTALLATION CONDITIONS 
The installation recommendation is based on the following environmental 
conditions; 
Ambient temperature between 5 to 40 °C (41 to 104 °F0 
Dry weather conditions 
Surface based on concrete, asphalt or pavement 
 
 
REQUIRED INSTALLATION MATERIALS 
The following would be required for mounting of the SENSIT IR.  
Equipment: 
 
 
Automatic core drill 
Drill size:  
 
 
Dimensions Ø 85 mm (3.35 in) 
Drill depth:  
 
 
55 mm (2.16 in) 
Filler material:    
 
Liquid rapid mortar  
Required amount per sensor: 
Approx 100 ml 
 
We have good results with the rapid mortar TM 5R. See appendix B for 
specifications. Ensure to follow the guidelines and instructions as outlined on the 
filler material.