N. V. Nederlandsche Apparatenfabriek NEDAP SENSITGW Manual Do Utilizador
SENSIT SYSTEM | MANUAL
Mounting The SENSIT IR
50/111
Mounting The SENSIT IR
11 MOUNTING THE SENSIT IR
SAFETY PRECAUTIONS
The following safety precautions should be observed during normal use, service and
repair:
repair:
x
The SENSIT
IR
may only be installed and serviced by qualified service
personnel.
x
To be sure of safety, do not modify or add anything to the SENSIT
IR
other
than mentioned in this manual or indicated by NEDAP N.V.
IC AND FCC ID
FCC ID: CGDSENSIT and IC: 1444A-SENSIT
DIMENSIONS
The SENSIT
IR
is designed for mounting into the floor of a parking space. See Figure
34 for the dimensions of the unit in mm.
Figure 34: Dimensions SENSIT IR (mm).
INSTALLATION CONDITIONS
The installation recommendation is based on the following environmental
conditions;
conditions;
x
Ambient temperature between 5 to 40 °C (41 to 104 °F0
x
Dry weather conditions
x
Surface based on concrete, asphalt or pavement
REQUIRED INSTALLATION MATERIALS
The following would be required for mounting of the SENSIT IR.
x
Equipment:
Automatic core drill
x
Drill size:
Dimensions Ø 85 mm (3.35 in)
x
Drill depth:
55 mm (2.16 in)
x
Filler material:
Liquid rapid mortar
x
Required amount per sensor:
Approx 100 ml
We have good results with the rapid mortar TM 5R. See appendix B for
specifications. Ensure to follow the guidelines and instructions as outlined on the
filler material.