C3.0 Multi Agile Remote Access Software Utilities
C3.0.1 Flash Update – Controller / Display
*
Do not power cycle the unit or use the Front Panel Buttons to configure the unit while it is
programming.
The operation of the Upconverters should not be affected during programming.
The Controller for the MA401xx, UC4040x and the DUAL4040x stores operating code in Flash Memory in order to
make it possible to update using the RS232 interface.
Procedure:
(1) 
Make sure that the MA401xx; UC4040x or DUAL4040x is in program mode:
To place the unit in program mode first press the module select button to ensure the display is active (back
light is on), press and hold the “Module Select” button and then press the “Up” button. A display on the LCD
should indicate that the unit is in program mode. To exit from program mode, simply repeat the key
sequence.
(2) 
Run the Multi Agile Remote Access Software and ensure that the COM Port settings are correctly chosen for
your PC.
(3) 
Select Flash Update from the menu then 4011 Flash. The Flash Update Utility will open another window
displaying:
(4) 
The latest revision flash files are automatically selected from the same directory as the Multi Agile
executable file. If the Multi Agile program was not installed to the default directory use the browse buttons to
locate the directory for the Multi Agile files.
(5)
 Click on the PROGRAM button to update the Flash memory.  This button will first program the FLASH
memory with the new code, and then verify the FLASH memory to confirm that programming was successful.
(NB:  Occasionally during this process, a message box indicating an Unknown Error will be
displayed.  You may close this box by pressing OK.  If this error occurs repeatedly, please exit and
restart the Multi Agile software and choose a slower baud rate before retrying the programming
operation.)