ActiGraph LLC 03 Manual Do Utilizador

Página de 21
 
 
 
 
actigraphcorp.com
 
49 E. Chase Street Pensacola, FL 32502   
tel (850) 332-7900 
fax (850) 332-7904 
TAS14DOC07 User’s Manual 
                    Page 11 of 21
 
Dynamic Range 
+/- 2000 
Deg/sec 
Table 2 – Gyroscope Key Specifications 
Magnetometer 
A three axis gyroscope collects angular velocity in units of degrees/sec.  Data is sampled at 100 Hz. 
Parameter 
Value 
Units 
Axis 
 
Sensitivity 
0.6 
µT/LSB 
Dynamic Range 
+/- 4800 
υT/LSB 
Table 3 – Magnetometer Key Specifications 
Steps 
Step counts are accumulated on a per-epoch basis and are based on accelerometer data collected on 
the vertical axis.  An algorithm present in the device firmware filters out the accelerometer’s baseline 
noise level to help accurately accumulate the steps-per-epoch. 
Inclinometer 
The inclinometer feature can help users identify the orientation of the device and, more importantly, 
when the device itself was taken off.  Each epoch is flagged with a number (1 through 4) to indicate the 
orientation of the device during that epoch.  For ActiGraph Link devices, this is done within the ActiLife 
software when converting the *.gt3x file to *.agd format.  As noted, the inclinometer feature is only 
valid when the device is worn vertically on the point of the hip.  
More details are available in the 
. 
Important   The inclinometer feature is only valid if the device is worn on the hip 
with Axis 1 upward facing. 
Inclinometer Code 
(Stored with each Epoch) 
Interpretation 
Device Off (Not Being Worn) 
Subject Standing 
Subject Lying Horizontal 
Subject Sitting 
Table 4 - Inclinometer Definitions