4.5
Setup 
Note
When doing a setup for a wideband DSP exciter, the net channel change
time must be set for 300 ms.
Refer to the DSP exciter VDT Menus and user manual for transmitter-control setup infor-
mation. All setup is done via the front-panel VT100 interface. 
4.6
Ultimate Disposition  
Caution
This equipment may contain hazardous materials.
Check with the local EPA or other environmental
authority before disposing of this equipment.
Table 4-5  Exciter Control Board Jumper Positions
Jumper
pre version 2.10 software
version 2.10 software
JW1
set to A for external 10 MHz oscillator
set to A for external 10 MHz oscillator
set to B for internal 10 MHz oscillator
set to B for internal 10 MHz oscillator
JW2
set to A for password protection
set to A for password protection
set to B to bypass password protection
set to B to bypass password protection
JW3
set to A for external VSWR protection
always set to B (for internal and/or ex-
ternal VSWR protection)
set to B for internal VSWR protection