Adtran SFP 1490/1310nm 10km 1442110G1 Folheto

Códigos do produto
1442110G1
Página de 2
C A U T I O N 
C A U T I O N ! 
SUBJECT TO ELECTROSTATIC DAMAGE
OR DECREASE IN RELIABILITY.
HANDLING PRECAUTIONS REQUIRED.
Warranty
: ADTRAN will replace or repair this product within the warranty period if it does not 
meet its published specifications or fails while in service. Warranty information can 
be found online at
©2008 ADTRAN, Inc. All Rights Reserved.
PRICING AND AVAILABILITY  800.827.0807
TECHNICAL SUPPORT  800.726.8663
RETURN FOR REPAIR  256.963.8722
*61442110G1-22A*
C
OMPLIANCE
Electrostatic Discharge (ESD) can damage electronic
modules. When handling modules, wear an antistatic
discharge wrist strap to prevent damage to electronic
components. Place modules in antistatic packing
material when transporting or storing. When working
on modules, always place them on an approved
antistatic mat that is electrically grounded.
The SFP is NRTL Listed to the applicable UL 
standards. The SFP meets or exceeds all the appli-
cable requirements of NEBS, Telcordia GR-63-CORE, 
and GR-1089-CORE. The SFP is intended for 
deployment in Central Office type facilities, EEEs, 
EECs, and locations where the NEC applies (for 
example, Customer Premises) and is intended to be 
installed by trained service personnel. Install the SFP 
in an ADTRAN product located in a restricted access 
location.
This device complies with Part 15 of the FCC rules. 
Operation is subject to the following two conditions:
1. This device may not cause harmful interference
2. This device must accept any interference 
received, including interference that may cause 
undesired operation.
Changes or modifications not expressly approved by 
ADTRAN could void the user's authority to operate 
this equipment.
♦  
Per GR-1089-CORE the ADTRAN system that the
SFP is being deployed in is designed and intended
for installation as part of a Common Bonding
Network (CBN). The ADTRAN system that the SFP
is being deployed in is not designed nor intended
for installation as part of an Isolated Bonding
Network (IBN).
♦  
Per GR-1089-CORE Section 9, the SFP does not
have an internal DC connection between battery
return and frame ground. The SFP can be installed
in a DC-I (isolated) or DC-C (common) installation.
For installations where other cards or the host
system have internal connections between battery
return and frame ground, the system would be
i n t e n d e d   f o r   d e p l o y m e n t   o n l y   i n   a   D C - C
installation.
♦   
The ADTRAN system chassis frame ground
terminal must be connected to an earth ground to
ensure that the metal enclosure of the SFP is
properly grounded via the backplane connector.
NOTE
The Gigabit Ethernet port(s) are optical and therefore
are not classified as any type of port as defined in
Appendix B of GR-1089-CORE Issue 4.
The SFP is designed to meet the following environ-
mental classes:
ETSI EN 300 019-1-1 “Classification of 
environmental conditions; Storage,” Class 1.2
ETSI EN 300 019-1-2 “Classification of 
environmental conditions, Transportation,” Class 
2.3
ETSI EN 300 019-1-3 “Classification of 
environmental conditions, Stationary use at 
weather-protected locations,” Class 3.3
The equipment is designed to function without degra-
dation during exposure to all test severities per Class 
3.3.