Intel Z520PT CH80566EE014DT Ficha De Dados

Códigos do produto
CH80566EE014DT
Página de 73
 
Electrical Specifications 
 
 
Datasheet   
 
33 
3.10 
CMOS Asynchronous Signals 
CMOS input signals are shown in Table 5. Legacy output FERR#, IERR#, and other 
non- AGTL+ signals (THERMTRIP# and PROCHOT#) use Open Drain output buffers. 
These signals do not have setup or hold time specifications in relation to BCLK[1:0]. 
However, all of the CMOS signals are required to be asserted for more than 5 BCLKs 
for the processor to recognize them. See Section 
3.12 for the DC specifications for the 
CMOS signal groups. 
3.11 
Maximum Ratings 
Table 6 specifies absolute maximum and minimum ratings. Within functional operation 
limits, functionality and long-term reliability can be expected. 
At conditions outside functional operation condition limits, but within absolute 
maximum and minimum ratings, neither functionality nor long term reliability can be 
expected. If a device is returned to conditions within functional operation limits after 
having been subjected to conditions outside these limits, but within the absolute 
maximum and minimum ratings, the device may be functional, but with its lifetime 
degraded depending on exposure to conditions exceeding the functional operation 
condition limits. 
At conditions exceeding absolute maximum and minimum ratings, neither functionality 
nor long term reliability can be expected. Moreover, if a device is subjected to these 
conditions for any length of time then, when returned to conditions within the 
functional operating condition limits, it will either not function or its reliability will be 
severely degraded.  
Although the processor contains protective circuitry to resist damage from static 
electric discharge, precautions should always be taken to avoid high static voltages or 
electric fields.