Intel SC5299UP SC5299UPNA Manual Do Utilizador

Códigos do produto
SC5299UPNA
Página de 154
Regulatory, Environmentals, and Specifications 
Intel
®
 Entry Server Chassis SC5299-E TPS 
  
Revision 
3.1 
Intel order number D37594-005 
134 
Table 141. System Office Environment Summary 
Parameter 
Limits 
Operating Temperature 
5°C to 40°C 
Non-Operating Temperature 
-40°C to 70°C 
Non-Operating Humidity 
35°C @ 90% RH 
Acoustic noise  
Workstation: TBD 
Shock, operating 
2g, 11 ms 1/2 Sine, 20g, 2ms, 1/2 Sine 
Shock, unpackaged 
25G Trapezoidal Shock 
Shock, packaged 
24" Free Fall, >40, <80lbs; 30" Free Fall, >20, <40lbs 
Vibration, unpackaged 
5Hz to 500Hz, 2.2 grms random profile 
Vibration, packaged 
5Hz to 500Hz, 1.09 grms random profile 
ESD 
2kV to 15 kV Air Discharge, 2kV to 8kV Contact Discharge 
System Cooling Requirement 
in BTU/hr 
 
9.8  BTU Information 
BTU, short for British Thermal Unit, is a British standard unit of energy. One BTU is equal to the 
amount of heat required to raise the temperature of one pound of liquid water by 1 degree 
Fahrenheit at its maximum density, which occurs at a temperature of 39.1 degrees Fahrenheit. 
One BTU is equal to approximately 251.9 calories or 1055 joules.  
The heat output of computer devices is often expressed in BTUs. The following table provides 
the BTU information for each SKU of the Intel
®
 Entry Server Chassis SC5299-E. 
Table 142. System BTU Information Table 
Power Supply 
Max Continuous Output 
Efficiency at 100% Loading 
BTU/hr 
SC5299UP (420W) 
450W 
70% 
2192 
SC5299DP (550W) 
550W 
70% 
2679 
SC5299BRP (650W) 
610W 
75% for power supply 
module 
85% for DC to DC 
3263 
SC5299WS (670W) 
670W 
68% 
3360