24-Hour Technical Support:   1-800-260-1312   International: 00-1-952-941-7600
 
 
16 
Connecting an alarm fixture, continued 
 
Fault indications 
Wire the relay contacts to any warning light or audible alarm in the control room as shown in 
Figure 13.  When a fault occurs, the relay contacts open, stopping the flow of current through 
the contact circuit.  This will disable the external alarm or turn OFF a light, indicating a fault.  
An alarm will occur under the following conditions: 
•  Power failure to either of the Industrial PoE Switch power inputs: 
o
  Power wires are disconnected, power source malfunction 
o
  Input power is something other than 48VDC 
 
 
 
Figure 13:  Alarm Relay Contacts