Hitachi RAF-35RPA RAF35RPA Manual Do Utilizador
Códigos do produto
RAF35RPA
ELECTRICAL
DATA
6-5
Model
Unit Main Power
Compressor Motor
VOL, PH, Hz
Fuse Rating (A) Min (V) Max (V) Locked Rotor Ampere (A)
STC
Cooling
Operation
Heating Operation
RNC
IPT
RNC
IPT
RAC-18WEA
220~230, 1, 50
15
198
253
N/A
2.78
2.91
494.4
3.00
564
RAC-25WEA
220~230, 1, 50
15
198
253
N/A
3.16
3.58
690
4.25
907.9
RAC-35WEA
220~230, 1, 50
15
198
253
N/A
4.81
5.00
1101.9
5.03
1122.7
RAC-50WEA
220~230, 1, 50
15
198
253
N/A
7.24
6.85
1617
7.29
1709.5
RAC-25FXA
220~230, 1, 50
16
198
253
N/A
3.99
2.66
580
3.63
790
RAC-35FXA
220~230, 1, 50
16
198
253
N/A
5.84
4.68
1020
5.860
1220
RAC-50FXA
220 ~ 230, 1, 50
16
198
253
N/A
8.2
7.16
1560
8.17
1780
RAC-25FPA
220~230, 1,50
16
198
253
N/A
2.93
3.34
630.3
4.11
839.7
RAC-35FPA
220~230, 1,50
16
198
253
N/A
3.81
4.30
869
4.81
1063.2
RAC-50FPA
220~230, 1,50
16
198
253
N/A
4.46
6.63
1436.8
7.29
1652.9
RAC-50DPA
220 ~ 240, 1, 50
30
198
264
N/A
10
6.4
1400
7.3
1590
RAC-60DPA
220 ~ 240, 1, 50
30
198
264
N/A
10
8.55
1870
9.75
2130
RAC-70DPA
220 ~ 240, 1, 50
30
198
264
N/A
10
11.6
2530
10.7
2340
VOL: Rated Unit Power Supply Voltage (V)
RNC:
Running Current (A)
HZ:
Frequency (Hz)
PH:
Phase (
)
STC: Starting Current (A)
IPT:
Input (W)
NOTE:
1. The above compressor data is based on 100% capacity combination of indoor units at the rated operating frequency
2. This data is based on the same conditions as the nominal heating and cooling capacities.
3. The compressor started by an inverter, resulting in extremely low starting current.