Emp Centauri ,Number of participants=8 MS9/8PIU-5 Ficha De Dados

Códigos do produto
MS9/8PIU-5
Página de 4
Always disconnect the product from the power grid before working on product, otherwise 
you risk the electric hazard. Pay attention to your safety if you have to enter places with a 
risk of fall.
In the case the product does not work and LED of power supply is on:
Check   if   the   terrestrial   and   satellite   antennas   are   correctly  fixed,   optimally  set   and 
connected to the product, satellite and terrestrial receivers turned on, plugged on and 
correctly set.
Check   the  connector   connections. The   inner   conductor   of   coaxial   cable   must   be  in 
contact with the inner conductor of F socket and the shielding of coaxial cable with F 
connector. Replace broken or interrupted coaxial cable.
Sometimes the reset of the multiswitch microprocessor is enough to fix the problem. 
Pull out the power plug of the multiswitch and satellite receiver from power grid and 
then re-plug them a few seconds later.
In the case the product does not work and LED of power supply is off or blinks:
Check that the product is connected to the power grid with AC voltage. If not, connect 
the product to the power grid with correct AC voltage.
Disconnect the product from the power grid and check that there is no short-circuit on 
the input satellite coaxial cables, which prevents the power supplying of LNBs. If yes, 
remove short-circuit and re-plug the product  into the power grid again.
The power supply can fail temporarily in case of overload or overheating. The cause can 
be current consumption of devices connected to the satellite inputs of product which 
exceeds the specifications, see section 2 Product Specifications. The next cause can be 
the overheating of product in consequence of wrong installation, see section 4 Product 
Storing and Installation. Disconnect the product from the power grid, remove the cause, 
and re-plug the product  into the power grid after a few minutes again.
If the failure cannot be removed, please contact your distributor.
10 S
 
 ymbols Explanation
 
 
certificate of conformity
international standard for digital satellite equipment control, number (1.0, 1.1, 1.2 
or 2.0) determines DiSEqC version.
for indoor use only
DC power supply
protective bonding
class II device
fuse protected
safety transformer
Power Supply Specifications
P3U27
Input Voltage
90-265 V AC, 50/60 Hz
Output Voltage
18 V DC, 12 V DC, 5 V DC
Maximum Output Current
1.0 A (18 V DC), 0.5 A (12 V DC), 0.5 A (5 V DC)
Maximum Output Power
27 W
Efficiency
75% min
Dimensions (w,d,h)
12.6 x 15.2 x 8.7 cm (power cord length 130 cm)
Temperature Range
-30 - +70 °C
3 Product Takeover
Make sure that the product is not damaged and following accessories are enclosed:
75 Ω loads for the impedance matching of unused outputs (2 pcs, others can be ordered 
from EMP-Centauri, code 1000066)
In the case of damage or missing accessories please contact your dealer.
4 Product Storing and Installation
The product must not be stored and installed:
in the place with excessive humidity,
in the place with excessive dust pollution, mechanical vibrations or impacts,
in the place out of temperature limits specified in the section 2 Technical Specifications,
close to heat sources (radiators or air ventilators, direct sunshine etc.),
in the reach of children
Do not expose the apparatus to dripping or splashing. Use the aparatus only in moderate climates 
(not in tropical climate). Fix the product firmly on a wall or another hard and inflammable surface 
with screws and dowels. The mains socket must be placed near the product. The mains plug 
shall remain readily operable. The mains socket and plug must be easily available.
The product shall be in no case held only by the connected cables.
Ensure the free space for the air circulation (space on sides and bellow the product 
should be at least 20 cm and the space over its top at least 50 cm).
Do not cover the product (with curtains etc.).
Do not place any containers with liquids (vases, glasses etc.) or naked flame sources 
(lighted candle etc.) on the product or near the product.
5 Product Connection
Connect the product in accordance with this manual and valid regulation in your country. Use 
high-quality 75 Ω coaxial cable designed for satellite reception. Mount the F connectors (screw, 
crimp or compress type) on the ends of coaxial cables, in the case of using the screw F connectors 
proceed according to the following picture and instructions:
1. Remove the outer coaxial cable coating in the length of approx. 15 mm.
2. Roll up the metal shielding braid and the shielding foil underneath and cut the shielding 
with scissors to approx. 5 mm.
6 of 8
3 of 8