3. Remove approx. 10 mm of the inner plastic insulation (approx. 5 mm of the insulation 
remains in a place).
4. Carefully screw the F connector on the cable end until the plastic insulation levels with 
the F connector opening.
5. Check there is no short between the inner conductor of coaxial cable and F connector.
The coaxial cables shall not be broken, the minimum bending radius should be 5 cm. Connect the 
F connectors into the F sockets of product and fasten them with an appropriate force.
Connect input F sockets marked A-H with convertors (LNBs) outputs according to the 
next table:
marking of F socket of 
multiswitch
marking of outputs of 
quatro LNB
marking of outputs of 
quad LNB
A
LNB A, V/L or 12V/0kHz
LNB A, any output
B
LNB A, H/L or 18V/0kHz
LNB A, any output
C
LNB A, V/H or 12V/22kHz
LNB A, any output
D
LNB A, H/H or 18V/22kHz
LNB A, any output
E
LNB B, V/L or 12V/0kHz
LNB B, any output
F
LNB B, H/L or 18V/0kHz
LNB B, any output
G
LNB B, V/H or 12V/22kHz
LNB B, any output
H
LNB B, H/H or 18V/22kHz
LNB B, any output
Connect input F socket marked TERR IN with output of terrestrial antenna, eventually 
with output of terrestrial antenna with terrestrial antenna preamplifier.
Connect output F sockets marked 1 to actual number of outputs of multiswitch with 
other   components   in   distribution   system  (satellite   receiver,  terrestrial   receiver,  wall 
socket etc.).
Connect connector marked with protective bounding symbol with protective bounding 
conductor, see section 10 Symbols Explanation.
Connect   the   mains   plug  into   the   mains   socket   with   voltage   according   to   section   2 
Technical Specifications.
In case when quad LNBs are used, it is necessary to switch on 22 kHz, see section 6 Product 
Settings. If some of outputs are not used, it is appropriate to terminate them with 75 Ohm loads. If 
not terminated, the specified terrestrial band insertion loss may not be kept.
The wiring examples are shown in the section 11 Wiring Diagrams or at the website www.emp-
centauri.eu.
6 Product Settings
For all satellite inputs, it is possible to change level of signals by means of attenuators in 15 dB 
range. The minimum attenuation is in clockwise stop position, the maximum attenuation is in 
counterclockwise stop position (for terrestrial input switching to passive mode, see below).  Set 
attenuators very gently, do not turn them behind stop positions by force.
22 kHz signal to satellite inputs for high band can be switched on/off and active/passive mode of 
terrestrial band can be selected by DIP switch located at left top side of the multiswitch.
Lever 4 in position OFF/ON switches on/off 22 kHz to satellite inputs C and D.
Lever 3 in position OFF/ON switches on/off 22 kHz to satellite inputs G and H.
Lever 1 in position OFF/ON switches active/passive mode of terrestrial band.
The return path is available in the passive mode. The lever is in ON position when closer to upper 
side of the multiswitch. The lever is in OFF position when closer to lower side of the multiswitch. 
Lever 4 is the closest to the multiswitch power supply.
If input F socket marked TERR IN is in short connection or maximal allowed current is exceeded 
(see section 2 Technical Specifications), the voltage decreases  down near to 0 V. Quality of 
signals is not affected  however.
Satellite receiver must be set up according to following table:
LNB
DiSEqC command for 
switching to given LNB
satellite receiver set up
LNB 1
Position 0 + Option 0
DiSEqC 1 or DiSEqC A (according to satellite receiver)
LNB 2
Position 1 + Option 0
DiSEqC 2 or DiSEqC B (according to satellite receiver)
7 Safety
Due to security reasons the product and wiring in which the product is connected, must be 
grounded properly. Use the terminal identified with the appropriate symbol to ground the 
product. Make sure the antennas are grounded properly.
Connect all devices to power grid only after all connections are finished and checked.
The product works with the AC voltage, see section 2 Technical Specifications. Make sure, 
that the local AC voltage corresponds to the operating voltage of product.
No objects can be placed on the mains cord for prevent its damage or break.  No hot objects 
should touch the mains cord.
While disconnecting the product from power grid, never pull the mains cord but the mains 
plug to prevent the mains cord damage.  Pay attention that the mains plug holds tight in the 
mains socket. Loose mains plug or mains socket means the danger of fire.
Never disassemble the product connected to the power grid, you risk the danger of electrical 
shock.
Never  work   on   the   wiring  (including  satellite   and   terrestrial   receivers,  TVs)   during   or 
before a storm. A lightning stroke into the antenna may cause dangerous overvoltage in the 
product metallic parts.
The product should be disconnected from the wiring immediately if it gets into contact with 
liquids (dropping water, spilled drinks etc.).
8 Product Maintenance
Always  disconnect the product from the power grid  and  wiring before performing any 
maintenance of the product. If you have to enter places with a risk of fall, pay attention to 
your safety.
Use only dry cloth to clean the product and do not use any liquid agents.
Coaxial   cables   installed   outdoors   should   be   replaced   once   in   a   few   years.  Unscrew   all   F 
connectors and clean connector contacts, resp. shorten the coaxial cable by approx. 2 cm,  every 2 
years.
Check the state of power supply and its  mains cord periodically. If the mains cord or the 
mains   plug   of   product   is   damaged,   it   must   be   replaced   by   manufacturer   or   qualified 
technician to prevent any dangerous situation. Let the product serviced if the housing of 
power supply is damaged.
If not used for long time, disconnect the product from the power grid.
9 Troubleshooting
4 of 8
5 of 8