The Data Bytes are labeled D0 through D7.  The far left bit in each byte is bit 7 and the far right 
bit is bit 0.  A “1” is always a dominant bit, and a “0” is always a recessive bit.  An “X” means that 
the bit can be either a 1 or a 0.  Select a bit value by touching the existing value and choosing a 
value from the pop-up menu.  The data bytes shown in the Binary trigger setup dialog are 
always in LSB (Least Significant Byte) format. 
DLC value represents the number of total data bytes in the CAN message, not the number of 
bytes you want to trigger on.  If you want to trigger on bit values in the 3
rd
 and 4
th
 bytes in an 8-
byte CAN message, then you must select the DLC to be 8, and select “X” values in the portion of 
the message that you don’t care to trigger on.   
 
Using CAN as a Trigger Qualifier   
Since the external CAN Trigger module is enabled with a simple pulse output and the standard 
oscilloscope Edge trigger, it is possible to set up Qualified SMART Triggers using the CAN Trigger 
pulse and another signal.   
For example, let’s assume that you wanted to trigger on the CAN signal only after a different 
signal (such as an analog signal) had gone above a certain threshold.  You could use the LeCroy 
Qualified SMART Trigger to set up that trigger condition, as shown below: 
 
The “Trigger On” condition is that of the normal pulse output from the CAN Trigger module, and 
the Qualifier is your analog signal.  
You can also set up a Pattern (Logic) and State trigger similarly.  This gives you powerful 