Lecroy WSXS-LINBUS TD WSXS-LINBUS TD trigger and decoder extension Compatible with LeCroy WaveSurfer® oscilloscopes. WSXS-LINBUS TD Manual Do Utilizador

Códigos do produto
WSXS-LINBUS TD
Página de 204
Serial Data Debug Solutions 
80 
919586 RevA 
FlexRaybus Trigger Setup Detail 
The following topic provides specific control settings for a FlexRaybus Trigger. 
 
All Trigger Setups use Source SetupFlexRay Setup, and Trigger Type fields. 
Other fields vary based on the Trigger Type Selections as follows: 
 
TSS (Start) and FrameTriggers hav
 fields. 
 
Frame Trigger has 
 fields. 
 
Symbol Trigger has 
 fields. 
 
Errors Trigger has 
 fields. 
Previously numbered FlexRaybus trigger sections correspond with the following explanations. 
1.
 
S
OURCES 
S
ETUP
 
 
DATA - The pop-up dialog is used to select the appropriate channel or EXT input for each. Set this field up 
with caution or your trigger may not function correctly. 
 
Threshold (Trigger)HighLow, and Find - Adjust the vertical level thresholds for the trigger. FlexRay is a 
tri-level signal and requires 2 voltage threshold settings which enable the oscilloscope to distinguish 
between 1 and 0. 
Like an Edge trigger, the level must be specified to process the incoming signals and determine if the 
desired serial data pattern meets the set trigger condition. 
If desired, use the automated Find Threshold button to detect and set appropriate thresholds. 
2.
 
F
LEX
R
AY 
S
ETUP
 
 
Bitrate - The FlexRay trigger can be configured to trigger on FlexRay signals at 2.5 Mb/s, 5 Mb/s and 10 
Mb/s as defined in the FlexRay specification. 
3.
 
T
RIGGER 
T
YPE
 
The FlexRay trigger can be configured to trigger on simple TSS (Start)FlexRay Frame (ID, Cycle Count, 
Frame Qualifiers)
FlexRay Symbols (CID, CAS/MTS and Wakeup Pattern), and Error Frame triggering is 
supported for FSS, BSS and FES, Header CRC and Payload CRC errors. 
Select the Trigger Type desired. The trigger dialog dynamically changes based on the selection made in 
the following manner: 
 
TSS (Start) - When selected, the Setup Format fields are shown and enabled. However, the Frame ID 
Setup, Cycle Count, and Frame Qualifiers fields, while shown, are disabled.