 UV exposure device
3.2
First commissioning
1.
Connect the unit to 230 V mains.
2.
Open the cover and activate the mains switch.
A buzzing of the vacuum pump must be had hear. Within approx. 30 seconds, a low air
pressure of approx. 
 bar must have built up (the film below the pressure screw is
sucked onto the edition pane).
Do not block the hole in the support pane if the pump is activated. It would be able to
shatter due to low air pressure.
 Do not remove or damage the film under the hinged pane.
 Press easily the support pane against the sponge rubber frame if no low air pressure is
built up; possibly, check the horizontal placement of the device (especially important in the
case of the device types 3 and 4).
 During film exposure with the double-sided exposure device, we recommend to cover the
support pane using an opaque base (e. g. pasteboard) since also with a switched-off
lower exposure box light is reflected from the bottom.
3.3
Operation of the timer
With the built-in timer, you can adjust the lighting duration of the UV tube. Time setting is
possible in seconds or minutes.
Minutes-/seconds
1 2
\
 display points
\
\
       
This point lights up if
the cover is opened.
These points only light up in the
‘Minute timer‘ operating mode
Rotating knob and push-button combination
for setting the operating mode and the time
and the  Start/Stop key
5