Causes of Error during Implementation
INSYS GSM does not react to commands
Possible cause:
Possible cause:
¾
The settings of the serial interface of the INSYS GSM and the terminal device do
not match.
Remedy:
¾
In the HSComm, synchronize the RS232 interface using the button "Synchronize
RS232".
¾
Adjust the settings.
¾
Reset the INSYS GSM to the default factory settings by pressing the reset key for a
prolonged period.
Note
If possible, use the serial interface directly. Problems during data
transmission may occur when USB serial converters are used.
If possible, use the serial interface directly. Problems during data
transmission may occur when USB serial converters are used.
No connection to the GSM network
Possible causes:
Possible causes:
¾
The signal quality of the GSM network is not sufficient. (see Chap. 3.9)
¾
The INSYS GSM is not logged in. (see Chap. Fehler! Verweisquelle konnte nicht ge-
funden werden.)
¾
The SIM card is not authorized for data connection. (see Chap. 2.5.4)
¾
The phone number is not selected or not correctly selected.
¾
The power supply for connections is not sufficient. (see Chap. 2.5.2)