Insys GSM 4.2 Compact 11-02-01-03-04.002 Manuale Utente

Codici prodotto
11-02-01-03-04.002
Pagina di 89
INSYS GSM 4.2  
INSYS GSM 4.2 compact 
 Initial 
Operation 
 
Sep-06 
            29 
3.8 
Causes of Error during Implementation 
INSYS GSM does not react to commands 
Possible cause: 
¾
  The settings of the serial interface of the INSYS GSM and the terminal device do 
not match. 
Remedy: 
¾
  In the HSComm, synchronize the RS232 interface using the button "Synchronize 
RS232". 
¾
  Adjust the settings. 
¾
  Reset the INSYS GSM to the default factory settings by pressing the reset key for a 
prolonged period. 
 
 
Note 
If possible, use the serial interface directly. Problems during data 
transmission may occur when USB serial converters are used. 
No connection to the GSM network 
Possible causes: 
¾
  The signal quality of the GSM network is not sufficient. (see Chap. 3.9) 
¾
  The INSYS GSM is not logged in. (see Chap. Fehler! Verweisquelle konnte nicht ge-
funden werden.
¾
  The SIM card is not authorized for data connection. (see Chap. 2.5.4) 
¾
  The phone number is not selected or not correctly selected. 
¾
  The power supply for connections is not sufficient. (see Chap. 2.5.2)