ConiuGo 700100107 EasyGuard II 700100107 Manual Do Utilizador
Códigos do produto
700100107
23
Revision 9.0
GSM Alarm & Telemetry systems
Modify Time Frame
------------------
DAY MONTH YEAR HOUR MINUTE
Name: TIME_ 1 Start: X X X X X
End: X X X X X
Weekdays: MON X TUE X WED X THU X FRI X SAT X SUN X
<1> Name
<2> Day
<3> Month
<4> Year
<5> Hour
<6> Minute
<7> Weekdays
<0> Back
Your choice:
------------------
DAY MONTH YEAR HOUR MINUTE
Name: TIME_ 1 Start: X X X X X
End: X X X X X
Weekdays: MON X TUE X WED X THU X FRI X SAT X SUN X
<1> Name
<2> Day
<3> Month
<4> Year
<5> Hour
<6> Minute
<7> Weekdays
<0> Back
Your choice:
On every change you have to set a starting time (Start) and an ending time (End).
“X” always indicates “don’t care”, meaning that this parameter is deliberately.
If just one parameter (“Start” or “End”) is defined by a “X” the system automatically
will set the other parameter to “X” as well.
If both parameters are set to the same value, the action starts exactly at this time
(e.g. Start = 10 and End = 10 starts the action exactly at 10 o’clock).
Example:
A measurements is required during office hours; start 09:00 (a.m.) finish 17:00 (5:00
p.m.) during Monday to Friday.
Number: 3 DAY MONTH YEAR HOUR MINUTE
Name: OFFICE Start: X X X 09 X
End: X X X 17 X
Weekdays: MON 1 TUE 1 WED 1 THU 1 FRI 1 SAT X SUN X
Name: OFFICE Start: X X X 09 X
End: X X X 17 X
Weekdays: MON 1 TUE 1 WED 1 THU 1 FRI 1 SAT X SUN X
<2> Digital Inputs:
Here you enter the basic informations and settings for the digital inputs. The number
of shown inputs in the software could be different to the real existing inputs on the
module itself. This depends on the software which is created also for extended ver-
sions of the module. If you have the standard configuration with 4 digital inputs there
are also the first 4 inputs important for you which are shown in the list.
If you choose now one of this inputs you could see the following screen: