ConiuGo 700100107 EasyGuard II 700100107 Manual Do Utilizador

Códigos do produto
700100107
Página de 54
 
24
 
Revision 9.0 
GSM Alarm & Telemetry systems 
 
Modify Digital Input 
------------------ 
Name: INPIN_1 
Hold time:(seconds) X 
 
<1> Name 
<2> Hold time 
 
<0> Back 
 
Your choice: 
 
Here  you  can  give  a  name  to  the  dedicated  input  (max.  10  characters).  This  gives 
you a better identification if you combine this input later with an action (see combina-
tion of actions and events). 
E.g.: If you have a switching contact connected to the first digital input which super-
vised a window, so it makes sin to name the input „WINDOW“. 
 
The digital inputs could use in combination with a hold time. The function of the hold 
time  depends  on  the signal  which  is  connected  to  this  input  (0  if  the  digital  input  is 
pulled to ground, 1 if the digital input is not connected to ground). 
 
Here the function is shown in the pictures below: 
 
 
In this case there is entered a hold time of 2 seconds. In case of an event the contact 
will  connected  to  ground.  In  this  constellation  the  hold  time  works  that  only  input 
signals  will  be  recognized  which  have  a  contact  time  of  2  seconds  or  longer.  Short 
signals will be ignored.