Microchip Technology MCP3425EV Ficha De Dados
![Microchip Technology](https://files.manualsbrain.com/attachments/cf42c3c895ef469f06d2e47e97fd98d738fcf5cf/common/fit/150/50/7340124dc8aa983aaf764094e2f06faab86f306c03111c5817f7e4e53fb2/brand_logo.gif)
© 2009 Microchip Technology Inc.
DS22072B-page 21
MCP3425
TABLE 5-4:
I
2
C SERIAL TIMING SPECIFICATIONS
Electrical Specifications: Unless otherwise specified, all limits are specified for T
A
= -40 to +85°C, V
DD
= +2.7V to +5.0V,
V
SS
= 0V, V
IN
+ = V
IN
- = V
REF
/2.
Parameters
Sym
Min
Typ
Max
Units
Conditions
Standard Mode (100 kHz)
Clock frequency
f
SCL
—
—
100
kHz
Clock high time
T
HIGH
4000
—
—
ns
Clock low time
T
LOW
4700
—
—
ns
SDA and SCL rise time
T
R
—
—
1000
ns
From V
IL
to V
IH
SDA and SCL fall time
T
F
—
—
300
ns
From V
IH
to V
IL
START condition hold time
T
HD:STA
4000
—
—
ns
START (Repeated) condition
setup time
setup time
T
SU:STA
4700
—
—
ns
Data hold time
T
THD:DAT
0
—
3450
ns
Data input setup time
T
SU:DAT
250
—
—
ns
STOP condition setup time
T
SU:STO
4000
—
—
ns
Output valid from clock
T
AA
0
—
3750
ns
Bus free time
T
BUF
4700
—
—
ns
Time between START and STOP
conditions.
conditions.
Fast Mode (400 kHz)
Clock frequency
T
TSCL
—
—
400
kHz
Clock high time
T
HIGH
600
—
—
ns
Clock low time
T
LOW
1300
—
—
ns
SDA and SCL rise time
T
R
20 + 0.1Cb
—
300
ns
From V
IL
to V
IH
SDA and SCL fall time
T
F
20 + 0.1Cb
—
300
ns
From V
IH
to V
IL
START condition hold time
T
HD:STA
600
—
—
ns
START (Repeated) condition
setup time
setup time
T
SU:STA
600
—
—
ns
Data hold time
T
HD:DAT
0
—
900
ns
Data input setup time
T
SU:DAT
100
—
—
ns
STOP condition setup time
T
SU:STO
600
—
—
ns
Output valid from clock
T
AA
0
—
1200
ns
Bus free time
T
BUF
1300
—
—
ns
Time between START and STOP
conditions.
conditions.
Note
1:
This parameter is ensured by characterization and not 100% tested.
2:
This specification is not a part of the I
2
C specification. This specification is equivalent to the Data Hold Time
(
THD:DAT
)
plus SDA Fall (or rise) time:
T
AA
= T
HD:DAT
+ T
F
(
OR
T
R
).
3:
If this parameter is too short, it can create an unintended Start or Stop condition to other devices on the bus line. If this
parameter is too long, Clock Low time (T
parameter is too long, Clock Low time (T
LOW
) can be affected.
4:
For Data Input: This parameter must be longer than t
SP
. If this parameter is too long, the Data Input Setup (T
SU:DAT
) or
Clock Low time (T
LOW
) can be affected.
For Data Output: This parameter is characterized, and tested indirectly by testing T
AA
parameter.