Microchip Technology MCP3425EV Ficha De Dados

Página de 38
MCP3425
DS22072B-page 22
© 2009 Microchip Technology Inc.
 High Speed Mode (3.4 MHz)
Clock frequency
f
SCL
3.4
MHz
C
b
 = 100 pF
1.7
MHz
C
b
 = 400 pF
Clock high time
T
HIGH
60
ns
C
b
 = 100 pF, f
SCL
 = 3.4 MHz
120
ns
C
b
 = 400 pF, f
SCL
 = 1.7 MHz
Clock low time
T
LOW
160
ns
C
b
 = 100 pF, f
SCL
 = 3.4 MHz
320
ns
C
b
 = 400 pF, f
SCL
 = 1.7 MHz
SCL rise time
(Note 1)
T
R
40
ns
From V
IL
 to V
IH
,
C
b
 = 100 pF, f
SCL
 = 3.4 MHz
80
ns
From V
IL
 to V
IH
,
C
b
 = 400 pF, f
SCL
 = 1.7 MHz
SCL fall time
(Note 1)
T
F
40
ns
From V
IH
 to V
IL
,
C
b
 = 100 pF, f
SCL
 = 3.4 MHz
80
ns
From V
IH
 to V
IL
,
C
b
 = 400 pF, f
SCL
 = 1.7 MHz
SDA rise time
(Note 1)
T
R: DAT
80
ns
From V
IL
 to V
IH
,
C
b
 = 100 pF, f
SCL
 = 3.4 MHz
160
ns
From V
IL
 to V
IH
,
C
b
 = 400 pF, f
SCL
 = 1.7 MHz
SDA fall time
(Note 1)
T
F: DATA
80
ns
From V
IH
 to V
IL
,
C
b
 = 100 pF, f
SCL
 = 3.4 MHz
160
ns
From V
IH
 to V
IL
,
C
b
 = 400 pF, f
SCL
 = 1.7 MHz
Data hold time
(Note 4)
T
HD:DAT
0
70
ns
C
b
 = 100 pF, f
SCL
 = 3.4 MHz
0
150
ns
C
b
 = 400 pF, f
SCL
 = 1.7 MHz
Output valid from clock
(Notes 2 and 3)
T
AA
150
ns
C
b
 = 100 pF, f
SCL
 = 3.4 MHz
310
ns
C
b
 = 400 pF, f
SCL
 = 1.7 MHz
START condition hold time
T
HD:STA
160
ns
START (Repeated) condition 
setup time
T
SU:STA
160
ns
Data input setup time
T
SU:DAT
10
ns
STOP condition setup time
T
SU:STO
160
ns
TABLE 5-4:
I
2
C SERIAL TIMING SPECIFICATIONS (CONTINUED)
Electrical Specifications: Unless otherwise specified, all limits are specified for T
A
 = -40 to +85°C, V
DD
 = +2.7V to +5.0V,
V
SS
 = 0V, V
IN
+ = V
IN
- = V
REF
/2.
Parameters
Sym
 Min
 Typ
 Max
Units
           Conditions
Note
1:
This parameter is ensured by characterization and not 100% tested.
2:
This specification is not a part of the I
2
C specification. This specification is equivalent to the Data Hold Time 
(
THD:DAT
plus SDA Fall (or rise) time:
 
T
AA
 = T
HD:DAT
 + T
F
 (
OR
 T
R
).
3:
If this parameter is too short, it can create an unintended Start or Stop condition to other devices on the bus line. If this 
parameter is too long, Clock Low time (T
LOW
) can be affected. 
4:
For Data Input: This parameter must be longer than t
SP
. If this parameter is too long, the Data Input Setup (T
SU:DAT
) or 
Clock Low time (T
LOW
) can be affected.
For Data Output: This parameter is characterized, and tested indirectly by testing T