LTC2607/LTC2617/LTC2627

26071727fa
operation
Table 2
COMMAND*
C3
C2
C1
C0
0
0
0
0 Write to Input Register
0
0
0
1 Update (Power Up) DAC Register
0
0
1
1 Write to and Update (Power Up)
0
1
0
0 Power Down
1
1
1
1 No Operation
ADDRESS*
A3
A2
A1
A0
0
0
0
0 DAC A
0
0
0
1 DAC B
1
1
1
1 All DACs
*Command and address codes not shown are reserved and should not be used.
Power-Down Mode
For power-constrained applications, the power-down mode 
can be used to reduce the supply current whenever one or 
both of the DAC outputs are not needed. When in power-
down, the buffer amplifiers, bias circuits and reference input 
are disabled and draw essentially zero current. The DAC 
outputs are put into a high impedance state, and the output 
pins are passively pulled to V
REFLO
 through 90k resistors. 
Input-register and DAC-register contents are not disturbed 
during power-down.
Either or both DAC channels can be put into power-down 
mode by using command 0100b in combination with the 
Figure 3
C3
1ST DATA BYTE
Input Word (LTC2607)
Write Word Protocol for LTC2607/LTC2617/LTC1627
C2 C1 C0 A3 A2 A1 A0
D13
D14
D15
S
W
A
SLAVE ADDRESS
1ST DATA BYTE
D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0
A
2ND DATA BYTE
A 3RD DATA BYTE
A
P
2607 F03
2ND DATA BYTE
INPUT WORD
3RD DATA BYTE
C3
1ST DATA BYTE
Input Word (LTC2617)
C2 C1 C0 A3 A2 A1 A0
D11
D12
D13
D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0
X
X
2ND DATA BYTE
3RD DATA BYTE
C3
1ST DATA BYTE
Input Word (LTC2627)
C2 C1 C0 A3 A2 A1 A0
D9
D10
D11
D8 D7 D6 D5 D4 D3 D2 D1 D0
X
X
X
X
2ND DATA BYTE
3RD DATA BYTE
appropriate DAC address. The 16-bit data word is ignored. 
The supply and reference currents are reduced by approxi-
mately 50% for each DAC powered down; the effective 
resistance at REF (Pin 9) rises accordingly, becoming a 
high-impedance input (typically > 1GΩ) when both DACs 
are powered down.
Normal  operation  can  be  resumed  by  executing  any 
command  which  includes  a  DAC  update,  as  shown  in 
Table 2 or performing an asychronous update (LDAC) as  
described in the next section. The selected DAC is powered 
up as its voltage output is updated. When a DAC in powered-
down state is powered up and updated, normal settling 
is delayed. If one of the two DACs is in a powered- down 
state prior to the update command, the power up delay is 
5µs. If on the other hand, both DACs are powered down, 
the main bias generation circuit has been automatically 
shut down in addition to the DAC amplifiers and reference 
input and so the power up delay time is
  12µs (for V
CC
 = 5V) or 30µs (for V
CC
 = 3V)
Asynchronous DAC Update Using LDAC
In addition to the update commands shown in Table 2, the 
LDAC pin asynchronously updates the DAC registers with 
the contents of the input registers. Asynchronous update 
is  disabled  when  the  input  word  is  being  clocked  into  
the part.