STMicroelectronics FlexSPIN: SPI configurable stepper and DC multi motor driver evaluation board EVAL6460 EVAL6460 Ficha De Dados
Códigos do produto
EVAL6460
Power bridges
L6460
60/139
Doc ID 17713 Rev 1
14.1.1 Full
bridge
When in full bridge configuration, the drivers will behave according to the following truth
table:
table:
Note:
Note: When “low power mode” is active, the bridges will enter in low power state and will
reduce its biasing thus contributing to the power saving.
reduce its biasing thus contributing to the power saving.
When a current limit event occurs this event will be latched and the bridges will remain in
high impedance state for the off time.
high impedance state for the off time.
Table 18.
Full bridge truth table
TSD
nRESET
Low
power
mode
Enable
Current
limit
MtrXCtrl
SideA
MtrXCtrl
SideB
PWM
OUT+
OUT-
1
X
X
X
X
X
X
X
Z
Z
0
0
X
X
X
X
X
X
Z
Z
0
1
1
X
X
X
X
X
Z
Z
0
1
0
0
X
X
X
X
Z
Z
0
1
0
1
1
X
X
X
Z
Z
0
1
0
1
0
0
0
X
0
0
0
1
0
1
0
0
1
0
1
1
0
1
0
1
0
0
1
1
0
1
0
1
0
1
0
1
0
0
1
1
0
1
0
1
0
1
0
1
1
0
0
1
0
1
0
1
1
X
1
1