STMicroelectronics FlexSPIN: SPI configurable stepper and DC multi motor driver evaluation board EVAL6460 EVAL6460 Data Sheet

Product codes
EVAL6460
Page of 139
   
   
   
Power bridges
L6460 
60/139
 Doc ID 17713 Rev 1
14.1.1 Full 
bridge
When in full bridge configuration, the drivers will behave according to the following truth 
table:
         
Note:
Note: When “low power mode” is active, the bridges will enter in low power state and will 
reduce its biasing thus contributing to the power saving. 
When a current limit event occurs this event will be latched and the bridges will remain in 
high impedance state for the off time.
Table 18.
Full bridge truth table
TSD
nRESET
Low 
power 
mode
Enable
Current 
limit
MtrXCtrl 
SideA
MtrXCtrl 
SideB
PWM
OUT+
OUT-
1
X
X
X
X
X
X
X
Z
Z
0
0
X
X
X
X
X
X
Z
Z
0
1
1
X
X
X
X
X
Z
Z
0
1
0
0
X
X
X
X
Z
Z
0
1
0
1
1
X
X
X
Z
Z
0
1
0
1
0
0
0
X
0
0
0
1
0
1
0
0
1
0
1
1
0
1
0
1
0
0
1
1
0
1
0
1
0
1
0
1
0
0
1
1
0
1
0
1
0
1
0
1
1
0
0
1
0
1
0
1
1
X
1
1