User interface 
 
2.7 Toolbars 
 
LOGO!Soft Comfort Online Help 
36
 
Operating Instructions, 06/2014 
Time control icons 
If you have programmed a time-sensitive circuit, you can use the time control to monitor the 
reaction of your circuit program. 
 
 
Start simulation for a specific time or number of cycles. 
Set the period and the number of cycles using the following icons. 
 
 
Set the period and the time base for a time-limited simulation or set a specific number 
of cycles 
 
Display the current time in LOGO!Soft Comfort 
 
Modify the current time in LOGO!Soft Comfort 
Data Table icon 
 
You can view VM (Variable Memory) values in a data table. For simulation, the values are 
updated each cycle. For online test, the values are updated after each communication. 
Status display 
Prerequisite: You can enable the display of signal states and process variables with the 
Tools → Options: Simulation (Page 121) command. 
The colored indication identifies the "1" or "0" status of a connecting line. By default, 
connection lines carrying a "1" signal are red while the lines carrying a "0" signal are blue. 
Example for the FBD Editor: 
 
PI controller trend view 
If your circuit program includes one or more PI controller function blocks, the simulation 
displays a trend view window of the analog output that shows the change in the AQ and PV 
values relative to the SP parameter over time. The trend view is continually updated while 
the simulation is in progress, at the frequency of the sample period that you configure. You