Finder Twilight switch for 35 mm DIN-rail, series 11.91.8.230 11.91.8.230.0000 2 - 150 lx 230 V/50-60 Hz 1 change-over c 11.91.8.230.0000 Ficha De Dados

Códigos do produto
11.91.8.230.0000
Página de 10
Features
Relays for automatic control of lighting according to
ambient light level - with separate light sensor
11.31 - 1 NO 16 A output contact
Sensitivity adjustment from 1 to 100 lux
One module, 17.5mm wide
Low energy consumption
24 V DC/AC supply version available
11.41 - 1 CO 16 A output contact
European patent “Zero hysteresis” for energy saving; 
Italian patent “Light feedback compensation” 
principle
Selector with 4 positions:
- Standard range (threshold setting 1...80 lx)
- High range (threshold setting 30...1000 lx)
- continuous light (helpful during installation and 
initial testing and for maintenance purposes)
- light off (useful for vacations)
For the first 3 working cycles the delay time 
(On and Off) is reduced to zero in order to aid 
installation
LED status indication
SELV separation between contact and supply circuit
Double insulation between supply and light sensor
35 mm rail (EN 60715) mount
Cadmium free contact material
Cadmium free light sensor (IC photo diode)
11.31
11.41
1 NO (SPST-NO)
1 CO (SPDT)
16 / 30 (120 – 5 ms)
16 / 30 (120 – 5 ms)
250 / 400 
250 / 400 
4,000
4,000
750
750
2,000
2,000
750
750
1,000
1,000
2,000
2,000
1,000 (10 / 10)
1,000 (10 / 10)
AgSnO
2
AgSnO
2
24
110…230 230
24
2.5 / 0.9  
5.2 / 2 
16.8…28.8
90…260
(0.8 …1.1) U
N
16.8…32
100 · 10
3
100 · 10
3
1…100
1…80
30…1,000
1.25 1
15 / 30 
15 / 30
–20…+50
–20…+50
IP 20 / IP 54
IP 20 / IP 54
Contact specification
Contact configuration
Rated current/Maximum peak current  (I
N
/I
max
) A
Rated voltage/Maximum switching voltage (U
N
/U
max
) V AC
Rated load AC1
VA
Rated load AC15 (230 V AC)
VA
Nominal lamp rating (230 V): incandescent W
compensated fluorescent W 
uncompensated fluorescent W
halogen W
Minimum switching load
mW (V/mA)
Standard contact material
Supply specification
Nominal voltage (U
N
)
V AC (50/60 Hz)
DC
Rated power
VA (50 Hz)/W
Operating range
V AC (50 Hz)
DC
Technical data
Electrical life at rated load in AC1
cycles
Threshold setting:
Standard range lx
High range lx
Hysteresis (switching Off/On ratio)
Delay time: switching On / Off 
s
Ambient temperature range
°C
Protection category: light dependent relay/light sensor
Approvals (according to type) 
1 pole
17.5 mm wide
1 pole
“zero hysteresis”
4 position selector
1
11 Series - Light Dependent Relay 12 - 16 A
For outline drawing see page 8
III-2013, www
.finder
net.com
11
SERIES