12   General Operation Descriptions   
OEM Specifications 
46 
12.1  Reset Response   
There are three types of reset in ATA as follows:   
Power On Reset (POR) 
The device executes a series of electrical circuitry diagnostics, spins up 
the HDA, tests speed and other mechanical parametric, and sets default 
values. 
COMRESET 
COMRESET is issued in Serial ATA bus. 
The device resets the interface circuitry as well as Soft Reset. 
Soft Reset (Software Reset)  SRST bit in the Device Control Register is set, then is reset. 
The device resets the interface circuitry according to the Set Features 
requirement. 
The actions of each reset are shown in “Table 29 Reset Response Table” on Page 46   
  
POR 
COMRESET 
Soft Reset
Aborting Host interface   
Aborting Device operation 
(*1) 
(*1) 
Initialization of hardware 
Internal diagnostic 
Starting spindle motor 
(*5) 
Initialization of registers (*2) 
Reverting programmed parameters to default 
(*6) 
(*3) 
    - Number of CHS (set by Initialize Device Parameter) 
 
 
 
  - Multiple mode 
 
 
 
  - Write cache 
 
 
 
  - Read look-ahead 
 
 
 
  - ECC bytes 
 
 
 
    - Volatile max address 
 
 
 
Power mode 
(*5) 
(*4) 
(*4) 
Reset Standby timer value 
O ---- execute   
X ---- not execute 
Note. 
(*1)  Execute after the data in write cache has been written. 
(*2)  Default value on POR is shown in “
(*3)  The Set Features command with Feature register = CCh enables the device to 
revert these parameters to the power on defaults. 
(*4)  In the case of sleep mode, the device goes to standby mode. In other case, 
the device does not change current mode. 
(*5)  According to the initial power mode selection. 
(*6) See 
12.13 Software Setting Preservation Feature Set. 
Table 29 Reset Response Table