Bunn AFPO-3 SL Manual Do Utilizador

Página de 25
13
BU
NN
Probe Boxes:
1.  Disconnect  the  signal  cable  from  the  probe 
boxes.
2.   Remove probe box from CDS hopper.
3.  Place the switch on the probe box in the “HIGH” 
position.
4.  Check the resistance across the box cable pins, 
see Fig. 10.
5.  With the probe box switch in the “LOW” position 
check the resistance across the pins, refer to Fig. 
10.
6.  If readings match the values indicated, the probe 
system is functioning properly.
Switch Removal and Replacement:
1.  Remove the #6 thread cutting screw securing the 
probe housing cover to the probe housing.
2.  Remove the wires from the switch terminals.
3.  Compress the clips inside the probe box and gently 
push the switch through the opening
4.  Push the new switch into the opening and spread 
the clips to hold switch in the autofill box.
5.  Refer to Fig. 11 when reconnecting the wires.
FIG. 8 PROBE SWITCHES 
SERVICE (cont.)
Location
 
The probe switches are located on the rear of each 
hopper, mounted in the probe housing cover.
Test Procedure
Probe System
1.  Disconnect  the  dispenser  from  the  power 
source.
2.  With the probe boxes connected to the signal cable, 
remove connector from refill box.
3.  Place the switch on the probe box in the “HIGH” 
position.
FIG. 11 PROBE LOW/OFF/HIGH SWITCH 
TERMINALS
P1540      
PROBE SYSTEM
P1523
4.  Check resistance across pins as shown in Fig. 9.
5.  With the probe box switch in “LOW” position check 
the resistance across the signal cable pins, see Fig. 
9.
6.  If  readings  match  values  indicated,  the  probe 
system is functioning properly. If not, check the 
probe boxes.
FIG. 9 SIGNAL CABLE PINS
P1538
BLU (HIGH) from Probe
Box Cable
GRN (OFF) from Probe
Box Cable
TAN (LOW) from Probe Box
Cable
P1539
FIG. 10 PROBE BOX CABLE PINS
AFPO-2
AFPO-3
AFPO-2 & 3