WHP Wireless DL360 Manual Do Utilizador

Página de 246
 Troubleshooting 
163 
 
Controller Communication Failure Occurred 
Description: Controller communication failure occurred. ADU was unable to 
successfully issue commands to the controller in this slot. 
Action
1.  Be sure all cables are properly connected and working. 
2.  Be sure the controller is working, and replace if needed. 
 
Controller Detected. NVRAM Configuration not Present 
Description: EISA NVRAM does not contain a configuration for this controller. 
Action: Run the server setup utility to configure the NVRAM. 
 
Controller Firmware Needs Upgrading 
Description: Controller firmware is below the latest recommended version. 
Action: Run Options ROMPaq to upgrade the controller to the latest firmware 
revision. 
 
Controller is Located in Special "Video" Slot 
Description: Controller is installed in the slot for special video control signals. If 
the controller is used in this slot, LED indicators on front panel may not function 
properly. 
Action: Install the controller into a different slot, and run the server setup utility 
to configure NVRAM. Then, run ACU to configure the controller.