 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide 
 
Controller Is Not Configured 
Description: Controller is not configured. If the controller was previously 
configured and you change drive locations, there may be a problem with 
placement of the drives. ADU examines each physical drive and looks for drives 
that have been moved to a different drive bay. 
Action: Look for messages indicating which drives have been moved. If none are 
displayed and drive swapping did not occur, run ACU to configure the controller 
and server setup utility to configure NVRAM. Do not run either utility if you 
believe drive swapping has occurred. 
 
Controller Reported POST Error. Error Code: X 
Description: The controller returned an error from its internal POST. 
Action: Replace the controller. 
 
Controller Restarted with a Signature of Zero 
Description: ADU did not find a valid configuration signature to use to get the 
data. NVRAM may not be present (unconfigured) or the signature present in 
NVRAM may not match the signature on the controller. 
Action: Run the server setup utility to configure the controller and NVRAM. 
 
Disable Command Issued 
Description: The issuing of the Accelerator Disable command has disabled 
posted-writes. This occurred because of an operating system device driver. 
Action: Restart the system. Run ACU to reinitialize the array accelerator board.