 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide 
 
Less Than 75% of Batteries at Sufficient Voltage Battery Pack X Below Reference 
Voltage 
Description: Battery pack on the array accelerator is below the required voltage 
levels. 
Action: Replace the array accelerator board if the batteries do not recharge 
within 36 powered-on hours. 
 
Logical Drive X Failed Due to Cache Error 
Description: This logical drive failed due to a catastrophic cache error. 
Action: Replace the array accelerator board and reconfigure using ACU. 
 
Logical Drive X Status = Failed 
Description: This status could be issued for several reasons: 
• 
Logical drive is configured for No Fault Tolerance, and one or more drives 
failed. 
• 
Mirroring is enabled, and any two mirrored drives failed. 
• 
Data Guarding is enabled, and two or more drives failed. 
• 
Another configured logical drive is in the WRONG DRIVE REPLACED or 
LOOSE CABLE DETECTED state. 
Action: Check for drive failures, wrong drive replaced, or loose cable messages. 
If a drive failure occurred, replace the failed drive or drives, and then restore the 
data for this logical drive from the tape backup. Otherwise, follow the procedures 
for correcting problems when an incorrect drive is replaced or a loose cable is 
detected.