WHP Wireless DL360 Manual Do Utilizador

Página de 246
172 
 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide 
 
Logical Drive X Status = Recovering (rebuilding data on a replaced drive) 
Description: A physical drive in this logical drive has failed and has now been 
replaced. The replaced drive is rebuilding from the mirror drive or the parity 
data. 
Action: No action is required. Normal operations can occur; however, 
performance will be less than optimal until after the rebuild process completes.  
 
Logical Drive X Status = Wrong Drive Replaced 
Description: A physical drive in this logical drive has failed. The incorrect drive 
was replaced. 
Action: Replace the drive that was incorrectly replaced. Then, replace the 
original drive that failed with a new drive.  
  CAUTION:  Do not run the server setup utility and try to 
reconfigure, or data will be lost. 
 
Loose Cable Detected - Logical Drives May Be Marked FAILED Until Corrected 
Description: ADU found a loose cable. The Smart Array Controller is unable to 
communicate with one or more physical drives. One or more logical drives may 
be marked FAILED, and are unusable until the problem is corrected. 
Action: Power down the system. Check the cables for a tight connection to the 
logical drives. Restart the system. If the error persists, the cables may be 
defective. 
 
Mirror Data Miscompare 
Description: Data was found at reset initialization in the posted-write memory; 
however, the mirror data compare test failed resulting in that data being marked 
as invalid. Data loss is possible. 
Action: Replace the array accelerator board.