Schlage CO-100 Manual Do Utilizador

Página de 12
4
CO-100 Offl ine Lock User Guide
GETTING STARTED 
Follow these steps when setting up a new lock.
1. Install the lock. See the installation guide that came with the lock, or visit 
www.schlage.com/support, for more information.
2. Test the lock for proper mechanical and electronic operation. See Testing on page 7 for more 
information.
3. When ready to set up for normal use, enter a new programming code, then program the user 
credentials. See Manual Lock Programming on page 5-6 for more information.
4. Familiarize yourself with the information in this guide.
Save this user guide for future reference.
CONSTRUCTION ACCESS MODE
Construction Access Mode is used to allow access before the lock has been programmed, and for 
testing purposes. Construction Access Mode is enabled by default.
Offl ine locks with keypads, have a default PIN of 13579 
and “ # ”, which can be used for installation, testing and 
construction access.
•  To test, enter the default PIN (13579 and “ # ”).
•  The Schlage button will blink and the lock will unlock.
•  The default PIN is automatically deleted when a new 
programming credential is created.
TIP
If you press the Default PIN code on a 
new lock and the code is not accepted, 
the lock has already been programmed.
If the new PIN is not known, or to put 
the lock back into construction access 
mode, reset the lock to factory settings. 
See Resetting To Factory Defaults on 
page 8 for more information.