Schlage CO-100 Manual Do Utilizador

Página de 12
5
CO-100 Offl ine Lock User Guide
 MANUAL LOCK PROGRAMMING
 
Left LED
Right LED
 Credential Types
Credential Type
Function
Description
Default  PIN
Programming
Used to program the lock – does not 
unlock the lock
Five-digit code
97531 and 
Normal Use
Unlocks the lock
PIN (3 - 6 digits)
13579 and 
Toggle
Changes the state of the lock unless in 
Freeze state
PIN (3 - 6 digits)
Freeze
Maintains the lock in current state until 
Freeze PIN is entered again
PIN (3 - 6 digits)
Pass-Through
Unlocks a lock momentarily, regardless
of state
PIN (3 - 6 digits)
Programming Legend
Symbol
Description
[Programming Code]
1
Five-digit code, identical to programming credential 
code listed in the Credential Types table.
[PIN]
Three- to Six-digit code. A PIN can be any of the PIN 
code types listed in the Credential Types table.
Asterisk key on the keypad
 - 
Number keys on the keypad
Schlage button
1  Programming codes such as 1-1-1 or 1-2-3-4 can be easily selected by non-authorized
users and should not be used.
TIP
Use the same 
programming code 
for all locks in the 
facility.