Procom AL500HYLA Manual Do Utilizador

Página de 14
                                 6                                                   AL058-01 
 
  CONNECTING TO GAS SUPPLY
                          Continued 
FUEL REQUIREMENTS: 
  Connect regulator/hose with standard 20-pound 
LP cylinder coupler.   
  Call the LP gas supplier to inspect the cylinder. 
Do not use a damaged LP gas cylinder. 
  Do not use LP gas without proper 
decompression. 
  Do not connect irregular LP gas supply with 
heater. 
 
Use only LP gas on this heater. Do not convert to 
other gases.
 
        CAUTION: It is dangerous to use a damaged 
or rusted cylinder. 
OPERATING HEATER 
This heater is designed for use with LP gas. You may 
light the heater directly. 
LP gas is heavier than air. If it leaks from joint, it may 
sink down to the floor and mix with ambient air to form 
a detonable mixture. If you have questions, contact 
your LP dealer for instructions or service. 
        Warning: Fire, burn, inhalation and explosion 
hazard. Keep solid combustibles, such as 
building materials, paper or cardboard, at safe 
clearances from the heater. Never use heater in 
the vicinity of gasoline, solvent, paint thinner or 
other combustibles. 
      Caution: When heater runs in the presence of 
other people, the user is responsible to properly 
offer those present safety precautions and 
hazard information. 
LIGHTING INSTRUCTIONS:
 
Follow adaptable lighting instructions. Apply soap 
solution to all joints. Bubbles forming show a leak. Do 
not use a match or an open flame to detect leak. Light 
heater after ensuring that no gas leak exists. 
START HEATER: 
1.  Turn the control valve knob clockwise to the “OFF” 
position. 
2.  Turn the door knob clockwise and open the heater 
door. 
3. Check all connections as described in the 
“Connecting to Gas” section of this manual on 
page 5. 
OPERATING HEATER
Continued 
4.  Fully open the valve on the propane cylinder. 
5. Push in gas control knob and turn it to IGN/ON 
position. Then Push and release the ignition button 
repeatedly until there is a flame at the pilot. 
6.  Keep control knob pressed in for 30 seconds after 
ignition, then release. 
7.  Turn the burner on to maximum rate and then set 
to desired setting or remain on HI. 
8.  Replace heater compartment door. 
TO TURN OFF HEATER: 
1.  Turn gas control knob to the “OFF” position. 
2.  If heater is not to be used, shut off cylinder valve. 
3. 
Do not attempt to relight heater within 5 minutes 
after the propane cylinder valve has been closed.
 
RESTART HEATER: 
1. Turn gas control knob clockwise to “OFF” position. 
2. Wait 5 minutes before restarting. 
3. 
Repeat step 5,6,7.
 
MAINTENANCE AND STORAGE
1. The Lp-gas supply cylinder to be used must be 
constructed and marked in accordance with the 
specifications for LP-gas cylinder of the U.S. 
Department of transportation. 
2.  Storage of an appliance indoors is permissible only 
if the cylinder is disconnected and removed from 
the appliance. Cylinders must be stored outdoors 
in a wellventilated area out of the reach of children. 
Disconnected cylinders must have threaded valve 
plugs tightly installed and must not be stored in a 
building, garage or any other enclosed area. 
3. The pressure regulator and hose assembly 
supplied with the appliance must be used and a 
statement that replacement pressure regulators 
and hose assemblies must be those specified by 
the appliance manufacturer. 
4. If the connection to the LP-gas cylinder is other 
than Type I, II or III (as described in the Standard 
for 
Cylinder Connection Devices, ANSI 
Z21.81/CGA 6.25), the cylinder with its mating 
fitting shall be provided by the appliance 
manufacturer. Supplying the cylinder may be 
accomplished by a method controlled by the 
manufacturer that will result in both the appliance 
and the cylinder being available at the time of 
purchase. 
5.  The cylinder supply system must be arranged for 
vapor withdrawal. 
6.  The cylinder used must include a collar to protect 
the cylinder valve.     
7.  Have the heater inspected by qualified service man 
before each use or at least annually. 
8.  Check the POL fitting for any damage before each 
use and replace if any damage is found. 
9.  Turn off cylinder valve when the heater is not to be 
used.