PowerDsine PD-6006 Manual Do Utilizador

Página de 16
 
PD-6006/12/24
 
Power over LAN Solutions 
10 
Cat. No.: 06-6800-056
Table  2-2: 
Port
 Status Indications 
Port LED Color 
Port Load Conditions 
Port Voltage 
Off 
Non-active load or 
unplugged port. 
Power to the port is disconnected.No 
DC voltage present on spare pairs. 
Green 
Active load is plugged in 
and complies with 
normal load conditions. 
Continuous nominal DC voltage is 
present on the spare pairs. 
Orange 
Overload conditions; or 
short; or forced external 
voltage feed (constant 
DC) into the port. 
Power to the port is disconnected. 
No DC voltage is present on the 
spare pairs. 
Green  blinking 
Transitional mode in 
which load detection is in 
process or discharged 
capacitor in the PD. 
Power to the port is disconnected. 
No DC voltage is present on the 
spare pairs. 
Orange blinking 
Total aggregated power 
exceeds pre-defined 
power budget. 
Power to the port is disconnected. 
No DC voltage is present on the 
spare pairs. 
 
2.4 Connectors 
The front panel of the Midspan includes a Console port (DB-9 connector). The 
user may connect a terminal and perform software loading, via this connector, 
using a standard null modem cable. The console port is set to 19,200-baud, 8 
data bits, no parity and 1 stop bit. Pin connections for this connector are: 
 
Pin 2 is Receive (RXD) 
 
Pin 3 is Transmit (TXD) 
 
Pin 5 is Ground 
 
Pins 1 and 6 are shorted 
 
Each data port is configured 
as shown in Figure 
 
2-2., as 
data route-thru ports for all 
data pins (pins 1, 2, 3 and 
6).Be certain to use 
Category 5 or higher cabling, 
as shown in the figure. 
Figure 
 
2-2: Connecting to 
the Midspan
DC -
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
RJ-IN
RJ-OUT
Ethernet
Switch
PD
RJ-45
RJ-45
Data
Data
Data
Data
Midspan Channel
Po
w
er
 Bu
s
Data
Data
Data
DC +
Data
DC -
DC +