PowerDsine PD-6006 Manual Do Utilizador

Página de 16
 
PD-6006/12/24
 
Power over LAN Solutions 
Cat. No.: 06-6800-056
2.3.2 Port 
Indications 
One bi-color indicator (green and orange), per port, provides port status: 
 
 
 
 
Green indicates that the terminal unit has been identified as 
"Power over LAN Enabled" and is active and receiving power. 
 
 
 
 
Orange indicates that the port is not supplying power and is 
not active.  
 
Refer to Table  2-2 for additional information.  
 
Note
 
Due to the standard detection process performed on each PoL 
port, power will not be supplied to an Ethernet device, that is not 
PoL-enabled (indicated in orange or off). In this way, Ethernet 
devices (not PoL-enabled) will not be affected by this connection. 
 
Table 
 
2-1: Power Status Indications 
Indicator 
Color 
Main Power 
Status 
Remarks 
Off 
Internal power 
supply unit is 
unplugged or 
faulty. 
Internal power supply voltage 
is too low. All ports are 
disconnected. 
Green 
Indicates AC 
power input 
active. 
Internal power supply voltage 
is within tolerance. 
AC 
Green 
blinking 
Internal power 
supply voltage is 
out of tolerance. 
All ports are disconnected. 
Off 
No DC input 
power available. 
DC input voltage is too low. 
All ports are disconnected. 
Green 
Indicates DC 
power input 
active. 
DC input voltage is within 
tolerance. 
DC 
Green 
blinking 
DC Input voltage 
is out of tolerance. 
All ports are disconnected. 
AC and DC 
Orange 
Internal problem 
alarm. 
Built in Test (BIT) failed.