Polycom Welding System 3725-77601-001H Manual Do Utilizador

Página de 560
 
Remote Alert Setup Operations
Polycom, Inc. 
515
 
3
Click Update.
Set Endpoint Alert Level Settings
Monitored endpoints send events to the CMA system. The CMA system 
categorizes and reports endpoint alerts into three alert levels: InfoMinor, or 
Major
By default the Alert Severity Level is set to Info for all of the Endpoint Alert 
Types it reports. You have these options:
• You can leave all of the Alert Severity Levels set to Info and create a 
remote alert profile for each endpoint type being monitored that allows 
you to notify all users assigned that profile about all endpoint events 
applicable to that endpoint type.
• You can change some of the Alert Severity Levels to either Minor or 
Major and create multiple remote alert profiles that notify different users 
of endpoint events of different types and severity levels. 
To set the endpoint alert level settings
1
Go to Admin > Alert Settings > Endpoint Alert Level Settings.
2
On the Endpoint Alert Level Settings page, change the Alert Severity 
Level for the different types of endpoint events as required.
Alert Type
Alert indicates...
Remote Control 
Battery Low
The battery in the endpoint’s remote needs to be 
replaced.
Credentials 
Required
The endpoint system requires that the user enter a valid 
username and password.
Credentials 
Failed
An attempt to log into the endpoint system failed.
HTTP Forbidden
The endpoint must be used in https: mode only.
Device Not 
Responding
The endpoint is not responding to the CMA system.
Heartbeat 
Timeout
The endpoint did not send a heartbeat to the CMA system 
within the required timeout period.
Gatekeeper 
Status Unknown
The CMA system gatekeeper cannot determine the 
connection status of the endpoint.
Gatekeeper 
Rejected
The CMA system gatekeeper rejected the endpoint’s 
attempt to register.
Gatekeeper 
Unregistered
The endpoint is not registered to the gatekeeper.